Go back to datasheets

VICTREX™ PEEK POLYMER ESD101

High performance thermoplastic material with tight electrostatic dissipative control and low outgassing. ESD performance not influenced by moulding conditions provided that recommended processing conditions are rigorously adhered to. Semi crystalline, granules for injection moulding, easy flow, colour black.

Applications in the semi-conductor industry were ESD control is essential while maintaining other performance requirements.

Material Properties
Physical

Nominal Value

Unit

Test Method

Density (Crystalline)

1.65

g/cm³

ISO 1183

Spiral Flow 1

14.0

cm

Internal Method

Molding Shrinkage 2

ISO 294-4

Across Flow

0.50

%

Flow

0.40

%

Mechanical

Nominal Value

Unit

Test Method

Tensile Modulus (23°C)

11500

MPa

ISO 527-1

Tensile Stress

ISO 527-2

Break, -55°C

145

MPa

Break, 23°C

125

MPa

Break, 120°C

80.0

MPa

Tensile Strain (Break, 23°C)

1.6

%

ISO 527-2

Flexural Modulus (23°C)

11000

MPa

ISO 178

Flexural Stress

ISO 178

-55°C

230

MPa

23°C

200

MPa

125°C

145

MPa

175°C

80.0

MPa

275°C

45.0

MPa

Impact

Nominal Value

Unit

Test Method

Notched Izod Impact Strength (23°C)

4.0

kJ/m²

ISO 180/A

Unnotched Izod Impact Strength (23°C)

25.0

kJ/m²

ISO 180
Hardness

Nominal Value

Unit

Test Method

Shore Hardness (Shore D, 23°C)

89.0

ISO 868
Thermal

Nominal Value

Unit

Test Method

Deflection Temperature Under Load (1.8 MPa, Unannealed)

258

°C

ISO 75-2/Af

Glass Transition Temperature

ISO 11357-2

Onset

143

°C

Midpoint

147

°C

Melting Temperature

343

°C

ISO 11357-3

CLTE - Flow

ISO 11359-2

< 143°C

25

ppm/K

> 143°C

70

ppm/K

CLTE - Average

ISO 11359-2

< 143°C

40

ppm/K

> 143°C

130

ppm/K

Thermal Conductivity

ISO 22007-4

23°C 3

0.45

W/m/K

23°C 4

0.65

W/m/K

Electrical

Nominal Value

Unit

Test Method

Surface Resistivity

Internal Method

-- 5

1.0E+7 to 1.0E+8

ohms

-- 6

1.0E+6 to 1.0E+7

ohms

Volume Resistivity 7 (23°C)

1.0E+8

ohms·cm

IEC 60093
Fill Analysis

Nominal Value

Unit

Test Method

Melt Viscosity (400°C)

275

Pa·s

ISO 11443
Additional Information

Nominal Value

Unit

Test Method

Outgassing

ASTM E595

Total Mass Loss, 24h : 125°C

0.24

%

Water Vapour Regained, 24h : 125°C

0.11

%

Typical Processing Information
Injection

Nominal Value

Unit

Drying Temperature

120 to 150

°C

Drying Time

3.0 to 5.0

hr

Hopper Temperature

< 100

°C

Rear Temperature

365

°C

Middle Temperature

370 to 375

°C

Front Temperature

380

°C

Nozzle Temperature

385

°C

Mold Temperature

180 to 220

°C

Injection Notes

Runner: Die / nozzle >3mm, manifold >3.5mm
Gate: >2mm or 0.5 x part thickness

Important notes:
1) Processing conditions quoted in our datasheets are typical of those used in our processing laboratories

  • Data for mould shrinkage should be used for material comparison. Actual mould shrinkage values are highly dependent on part geometry, mould configuration, and processing conditions.
  • Mould shrinkage differs for along flow and across flow directions. “Along flow” direction is taken as the direction the molten material is travelling when it exits the gate and enters the mould.
  • Mould shrinkage is expressed as a percent change in dimension of a specimen in relation to mould dimensions.

2) Data are generated in accordance with prevailing national, international and internal standards, and should be used for material comparison. Actual property values are highly dependent on part geometry, mould configuration and processing conditions. Properties may also differ for along flow and across flow directions.

Detailed data available on our website www.victrex.com or upon request.

Notes
1Mold Temperature: 180°C, Melt Temperature: 385°C, 1.00 mm
2385°C nozzle, 180°C tool
3Average
4Along flow
523°C, 10V
623°C, 100V
7100V

Hi, do you have PEEK questions I can help with?